660 Works

PTB-Jahresbericht 2005

PTB-Jahresbericht 2008

PTB-Jahresbericht 2010

PTB-Jahresbericht 2012

PTB-Jahresbericht 2017

Metrology for Biological Radiation Effects – Status and Metrological and Research Needs

Woon Yong Baek, Marion Ute Bug, Volker Dangendorf, Ulrich Giesen, Gerhard Hilgers & Hans Rabus
Progress in the field of ionizing radiation metrology achieved in the BioQuaRT project raised the question to what extent radiobiological investigations would benefit from metrological support of the applied methodologies. A panel of experts from the medical field, fundamental research and radiation protection attended a workshop at PTB to consult on metrology needs related to biological radiation effects. The panel identified a number of metrological needs including the further development of experimental and computational techniques...

Zündtemperaturen in großen Behältern

Elisabeth Brandes & Werner Hirsch
Es wurde die Zündtemperatur ausgewählter Substanzen (Reinstoffe und Gemische) in Gefäßen zwischen 0,2 l (Normapparatur) und 0,5 m3 bestimmt. In Übereinstimmung mit theoretischen Überlegungen und bekannten empirischen Gleichungen nimmt die Zündtemperatur mit dem Logarithmus des Gefäßvolumens ab. Bei Stoffen, die bei Temperaturen unterhalb der Normzündtemperatur kalte Flammen ausbilden können, gilt diese Beziehung jedoch erst bei Volumina größer als ca. 1 l 5 l, im Bereich kleinerer Volumina ist die Abnahme der Zündtemperatur wesentlich stärker. Wird...

Towards a TDLAS based optical gas standard for the absolute HCl measurements in flue gases from combustion process

Zhechao Qu, Olav Werhahn & Volker Ebert
European Directives are coming into force setting increasingly stringent Emission Limit Values (ELVs) for regulating emissions from e.g. combustion processes. Optical methods offer promising tools to investigate the dynamic release of molecular species from combustion environments. One of the most widely used optical technique to meet the high sensitivity, online and in situ requirements is laser-based absorption spectroscopy, in particular tunable diode laser absorption spectroscopy (TDLAS), which is frequently applied in combustion research and industry...

Von Würfeln und Partitionen

Alexander Bender & Amin Thainat
Junge Wissenschaft. Paper 07/2019

Wettrennen gegen den Computer

Ferdinand Krämer
Junge Wissenschaft. Paper 07/2019

PTB-Anforderungen 12.10 „Geschwindigkeitsmessgeräte mit aufgeweitetem Laserstrahl (stationär, semistationär, transportabel)“. Ausgabe November 2019

Diese PTB-Anforderungen behandeln folgende Messgeräte nach § 1 Absatz 1 Nummer 12 Buchstabe a der Mess- und Eichverordnung zur Bestimmung von Messgrößen im öffentlichen Verkehr zur amtlichen Überwachung: Geschwindigkeitsmessgeräte mit aufgeweitetem Laserstrahl (stationär, semistationär, transportabel). Diese PTB-Anforderungen enthalten Anforderungen zu technischen Spezifikationen und Verwendungspflichten für Geschwindigkeitsmessgeräte mit aufgeweitetem Laserstrahl. Sie wurden von der PTB unter Beteiligung der betroffenen Kreise erstellt. Diese PTB-Anforderungen bestehen aus zwei Teilen. Der erste Teil behandelt Regeln und technische Spezifikationen für...

Effects of the spatial heterogeneity of gas matrix and thermal boundary layers on absolute TDLAS HCl measurements in hot flue gases

Zhechao Qu, Javis Nwaboh, Olav Werhahn & Volker Ebert
European Directives are coming into force setting increasingly stringent Emission Limit Values (ELVs) for key air pollutants and regulating emissions from combustion processes. Accurate meas-urement of emissions to the atmosphere is vital to control and reduce air pollution. Optical methods offer promising tools to investigate the dynamic release of molecular species from combustion envi-ronments. The IMPRESS 2 project [1] goes beyond state of the art in measuring the emissions of critical pollutants (e.g. HCl) with...

Kalibrierung von Einzelhubdispensern und Kolbenbüretten : Richtlinie DKD-R 8-3

Braunschweig Physikalisch-Technische Bundesanstalt
Diese Richtlinie legt Mindestanforderungen an das Kalibrierverfahren einschließlich der Beachtung von speziellen Einflüssen und Messunsicherheitsbeiträgen bei der Kalibrierung von Einzelhubdispensern und Kolbenbüretten ohne und mit Motorantrieb fest. Die Definitionen und Anforderungen beziehen sich bei Geräten mit Wechsel-Dosiereinheiten auf die Kombination von Grundgerät und verwendeter Dosiereinheit.

Der Erkenntniswert von Statistikdatei, gesamter Messreihe und Annullationsrate in der amtlichen Geschwindigkeitsüberwachung

Die sogenannte Statistikdatei, die Messreihe sowie die Anzahl der Annullationen können zur Überprüfung einer einzelnen Geschwindigkeitsmessung nichts beitragen.

In der Falle

Christoph Schütze, Sarah Schnöge & Fabian Obermair
Junge Wissenschaft. Paper 03/2020

Long Slender Piezo-Resistive Silicon Microprobes for Fast Measurements of Roughness and Mechanical Properties inside Micro-Holes with Diameters below 100 µm

Uwe Brand, Min Xu, Lutz Doering, Jannick Langfahl-Klabes, Heinrich Behle, Sebastian Bütefisch, Thomas Ahbe, Bodo Mickan, Erwin Peiner, Stefan Völlmeke, Thomas Frank, Ilia Kiselev, Michael Drexel & Michael Hauptmannl
During the past decade, piezo-resistive cantilever type silicon microprobes for high-speed roughness measurements inside high-aspect-ratio microstructures, like injection nozzles or critical gas nozzles have been developed. This article summarizes their metrological properties for fast roughness and shape measurements including noise, damping, tip form, tip wear, and probing forces and presents the first results on the measurement of mechanical surface parameters. Due to the small mass of the cantilever microprobes, roughness measurements at very high traverse...

Determination of individual measurement uncertainty components according to DIN EN ISO 6789-2:2017 : Guide DKD-L 10-1

Braunschweig Physikalisch-Technische Bundesanstalt
The standard DIN EN ISO 6789-2:2017 Assembly tools for screws and nuts - Hand torque tools - Part 2: Requirements for calibration and determination of measurement uncertainty (ISO 6789-2:2017), German version EN ISO 6789-2:2017 describes a calibration procedure for torque tools, including the determination of the measurement uncertainty. DKD-L 10-1 has been prepared to specify the application of the DIN standard. In particular, the determination of the measurement uncertainty by means of statistical methods is...

Calibration of conditioning amplifiers for dynamic application : Guideline DKD-R 3-2

Sensors for kinematic or mechanical measuring variables such as acceleration, angular velocity (rotation rate), force, torque or pressure are extended by a conditioning amplifier to be connected to data logging and/or display systems. In combination with this amplifier, the sensor forms a measuring chain. To ensure the exchangeability of the components of this measuring chain, sensor and amplifier are to be characterised individually. This guideline describes validated methods for the characterisation of conditioning amplifiers of...

Statische Kalibrierung von Drehmomentmessgeräten mit Wechseldrehmoment : Richtlinie DKD-R 10-5 Revision 1

Braunschweig Physikalisch-Technische Bundesanstalt
Diese Richtlinie ergänzt DIN 51309:2005-12 um die Kalibrierung von Drehmomentmessgeräten mit Wechseldrehmoment.

13th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions, Proceedings

Florian Baumann, Michael Beyer, Elisabeth Brandes, Jens Brunzendorf, Sai charan singh Chowhan, Ghazaleh Esmaeelzade, Stefan Essmann, Holger Grosshans, Michael Hau, Vanessa Heilmann, Michael Hilbert, Matthias Himstedt, Werner Hirsch, Tim Krause, Johann-Robert Kummer, Frank Lienesch, Detlev Markus, Dieter Möckel, Thomas Stolz, Nuki Susanti, Adeyemi Taiwo, Martin Thedens, Carsten Uber, Sabine Zakel, Zaheer Abbas … & Yao Zhao
It is our pleasure to present the proceedings of the 13th International Symposium on Hazards, Prevention, and Mitigation of Industrial Explosions (ISHPMIE). The publication of these proceedings was heavily affected by the global situation. In light of these challenges, we are happy to compile proceedings consisting of 84 high-quality papers that reflect the scientific state-of-the-art in the following topical categories: Advances in explosion protection: Strategies, measures, and protective equipment; Detonations and DDT; Electro-chemical energy carriers;...

PTB-Prüfregeln: Therapiedosimeter mit Ionisationskammern für Photonenstrahlungen mit Energien unterhalb von 3 MeV

PTB-Prüfregeln, Band 16

PTB-Prüfregeln: Störfestigkeit: Verfahren zur Prüfung des Einflusses elektromagnetischer Störgrößen auf Meßgeräte

PTB-Prüfregeln, Band 17

PTB-Prüfregeln: Geldspielgeräte nach § 33c Gewerbeordnung mit Anhang „Meßschnittstelle für Geldspielgeräte“

PTB-Prüfregeln, Band 23

Merkblatt für Anträge auf Bauartzulassung von Spielgeräten mit Gewinnmöglichkeit: (Geld- und Warenspielgeräte) nach § 33c bzw. § 60a der Gewerbeordnung (GewO)

Merkblatt zur PTB-Prüfregel Band 23

PTB-Prüfregeln: Meßgeräte für Gas: Meßgeräte für den Kohlenstoffdioxidanteil in Brenngasen

PTB-Prüfregeln, Band 24

Registration Year

  • 2021
    4
  • 2020
    120
  • 2019
    122
  • 2018
    105
  • 2017
    26
  • 2016
    56
  • 2015
    121
  • 2014
    52
  • 2013
    53
  • 2012
    1

Resource Types

  • Text
    640
  • Dataset
    17
  • Image
    2
  • Collection
    1