790 Works

Anomalies in multiline-TRL-corrected measurements of short CPW lines

Gia Ngoc Phung & Uwe Arz
Microwave probes in on-wafer measurements contribute to a number of parasitic effects deteriorating the accuracy of multiline Thru Reflect Line (mTRL) calibrations. The accuracy of mTRL calibration is especially sensitive in Devices under Test (DUTs) of shorter line length. It has been demonstrated in previous experimental studies that the calibrated results are often only reliable as long as the length of the line is at least 2 mm. However, the reasons behind this phenomenon have...

Anwendung des Ersatzlastverfahrens zur Kalibrierung von nichtselbsttätigen Waagen : Expertenbericht DKD-E 7-1

Der Expertenbericht basiert auf der Kalibrierrichtlinie DKD-R 7-2, Ausgabe 01/2018 [Übersetzung des EURAMET Calibration Guide No.18 Version 4.0 (11/2015)]. Der Expertenbericht beinhaltet ergänzende Anforderungen zur praktischen Durchführung des Ersatzlastverfahrens und unterstützt die erforderliche hohe Kompetenz eines akkreditierten Kalibrierlaboratoriums. Das Ersatzlastverfahren ist im Kapitel 4.3.3 der DKD-R 7-2 beschrieben. Durch die Anwendung des Ersatzlastverfahrens erhöht sich mit jedem Ersatzlastschritt der Messunsicherheitsbeitrag der verwendeten Last und somit die im Kalibrierschein anzugebende Messunsicherheit der Waage. Das Ersatzlastverfahren wird...

2nd international DCC-Conference 01 - 03 March 2022 Proceedings

Héctor Laiz, Siegfried Hackel, Frank Härtig, Thorsten Schrader, Shanna Shanna, Jan Loewe, Lutz Doering, Benjamin Gloger, Justin Jagieniak, Daniel Hutzschenreuter, Gamze Söylev-Öktem, Pawat Phuaknoi, Kittisun Mongkolsuttirat, Narin Chantawong, Wasin Limthunyalak, Jariya Buajarern, Robert Hanisch, James Antony Fedchak, Steven Choquette, Caterine Rimmer, Benjamin Long, Raymond Plante, Katrice Lippa, Dinis Camara, Sari Saxholm … & Thomas Krah
PTB organized the second International DCC Conference from 01 to 03 March 2022. The conference was held as an all-digital event. The technical scope of the conference focused on current advances of the Digital Calibration Certificate (DCC), the use of the Digital SI System (D-SI), including but not limited to implementation, current applications, good practices, and middleware. Attendees from around the world were invited to share and learn a great deal about the DCC. The...

Anleitung zur Nutzung des DCC-Schemas für die Erstellung eines digitalen Kalibrierscheins für Gewichte : Expertenbericht DKD-E 7-2

Die voranschreitende Digitalisierung hält auch nicht vor dem Bereich der Kalibrierung. Angetrieben auch aus der Industrie wurde daher der digitale Kalibrierschein (DCC) entwickelt. Dabei handelt es sich um eine XSD-Schemadatei, die als eine Art Vorlage für digitale Kalibrierscheine für alle Messgrößen im XML-Format dient. Eine Umsetzung braucht daher immer noch weitere, fachspezifische Festlegungen. Um die Anwendungsmöglichkeit für die Massekalibrierung von Gewichten und Gewichtssätzen zu prüfen und die damit verbundenen Festlegungen zu treffen, ist im DKD-Fachausschuss...

Calibración de amplificadores de medida para aplicaciones dinámicas : Directriz DKD-R 3-2

Braunschweig Physikalisch-Technische Bundesanstalt
Los sensores para magnitudes cinemáticas o mecánicas, como la aceleración, la velocidad angular, la fuerza, el par o la presión, suelen necesitar un amplificador (inglés: conditioning amplifier) para poder conectarse a los sistemas de adquisición y/o visualización de datos. Junto con este amplificador (a menudo también denominado adaptador), el sensor forma una cadena de medida. Para que los componentes de esta cadena de medida sean intercambiables, se requiere una caracterización individual del sensor y del...

Mit Schwung nach oben

Max Schaldach
Junge Wissenschaft. Paper 03/2022

Metrologie und KI: Die KI-Strategie der PTB

Sascha Meyne, David Auerbach, Tobias Klein, Matthias Neuwirth, Ulrike Ankerhold, Mathias Anton, Stefan Pojtinger, Ketelhut Steffen, Tobias Schäffter, Hans Rabus, Lukas Winter, Andreas Kofler, Christoph Kolbitsch, Patrick Schünke, Markus Bär, Clemens Elster, Lara Hoffmann, Sebastian Heidenreich, Stefan Haufe, Martin Nischwitz, Marko Esche, Andreas Barthel, Dirk Ratschko, Harry Stolz, Sascha Eichstädt … & Daniel Lübbert
PTB-Mitteilungen. Band 132 (2022), Heft 1. ISSN 0030-834X

Dataset for the publication \"Investigating the Trackability of Silicon Microprobes in High-Speed Surface Measurements\"

Min Xu, Zhi Li, Michael Fahrbach, Erwin Peiner & Uwe Brand
High-speed tactile roughness measurements set high demand on the trackability of the stylus probe. Because of the features of low mass, low probing force, and high signal linearity, the piezoresistive silicon microprobe is a hopeful candidate for high-speed roughness measurements. This paper investigates the trackability of these microprobes through building a theoretical dynamic model, measuring their resonant response, and performing tip-flight experiments on surfaces with sharp variations. Two microprobes are investigated and compared: one with...

Optimization of a Self-darkening System

Adrien Jathe
Junge Wissenschaft. Paper 08/2021

PTB-Anforderungen 12.04 „Verkehrsradargeräte (stationär, transportabel)“. (11/2021)

Diese PTB-Anforderungen behandeln folgende Messgeräte nach § 1 Absatz 1 Nummer 12 Buchstabe a der Mess- und Eichverordnung zur Bestimmung von Messgrößen im öffentlichen Verkehr zur amtlichen Überwachung: Verkehrsradargeräte (stationär, transportabel). Diese PTB-Anforderungen enthalten Anforderungen zu technischen Spezifikationen und Verwendungspflichten für Verkehrsradargeräte. Sie wurden von der PTB unter Beteiligung der betroffenen Kreise erstellt. Diese PTB-Anforderungen bestehen aus zwei Teilen. Der erste Teil behandelt Regeln und technische Spezifikationen für Verkehrsradargeräte, um die wesentlichen Anforderungen an diese...

Sinking Bubbles

Ophélie Lèna Riviére
Junge Wissenschaft. Paper 09/2021

Ringvergleich Flüssigkeiten Durchflussbereiche: 0,08 m³/h … 1,20 m³/h 0,90 m³/h … 9,00 m³/h 60,00 m³/h … 600,00 m³/h Juni 2017 bis Dezember 2020 : Vergleichsbericht DKD-V 11-3

Enrico Frahm
Das Ziel dieses Ringvergleiches „Flüssigkeiten“ war die Bestätigung der akkreditierten Messunsicherheiten der teilnehmenden Laboratorien und Prüfstände. Die Bestätigung erfolgte über den Vergleichsreferenzwert y (engl.: reference value) und den Grad der Übereinstimmung EN (engl.: degree of equivalence) der Laboratorien im Vergleich zu diesem Referenzwert. Die PTB stellte als nationales Metrologieinstitut bei drei verwendeten Transfergeräten das Referenzlabor und durch die eigenen Messungen den Referenzwert. Bei einem vierten Transfergerät wurde der Referenzwert aus den Messwerten der beteiligten Laboratorien...

Elektrostatische Aufladung beim Versprühen von Wasser – Untersuchung praxisrelevanter Prozesse bei der Reinigung kleiner und mittelgroßer Behälter

Florian Baumann, Matthias Himstedt, Dieter Möckel, Martin Thedens & Michael Beyer
PTB-Bericht MA-100

PTB-Anforderungen 12.07 „Weg-Zeit-Messgeräte mit Helligkeitssensoren (stationär, semistationär, transportabel)“. Ausgabe Juli 2022

Diese PTB-Anforderungen behandeln folgende Messgeräte nach § 1 Absatz 1 Nummer 12 Buchstabe a der Mess- und Eichverordnung zur Bestimmung von Messgrößen im öffentlichen Verkehr zur amtlichen Überwachung: Weg-Zeit-Messgeräte mit Helligkeitssensoren (stationär, semistationär, transportabel). Diese PTB-Anforderungen enthalten Anforderungen zu technischen Spezifikationen und Verwendungspflichten für Weg-Zeit-Messgeräte mit Helligkeitssensoren. Sie wurden von der PTB unter Beteiligung der betroffenen Kreise erstellt. Diese PTB-Anforderungen bestehen aus zwei Teilen. Der erste Teil behandelt Regeln und technische Spezifikationen für Weg-Zeit-Messgeräte mit...

Thermoelectric measurements in magnetic nanowires

Alexander Fernández Scarioni
PTB-Bericht E-116

Registration Year

  • 2022
    60
  • 2021
    74
  • 2020
    120
  • 2019
    122
  • 2018
    105
  • 2017
    26
  • 2016
    56
  • 2015
    121
  • 2014
    52
  • 2013
    53

Resource Types

  • Text
    753
  • Dataset
    34
  • Image
    2
  • Collection
    1