Progressing dTDLAS based HCl Optical Gas Standards - towards meeting type approval requirements of EN 15267 4

Zhechao Qu, Olav Werhahn & Volker Ebert

Calibration of Pressure Gauges : Guideline DKD-R 6-1, Revision 3

This guideline serves to establish minimum requirements for the calibration procedure and the evaluation of the measurement uncertainty in the calibration of pressure gauges. It applies to Bourdon tube pressure gauges, electric pressure gauges and pressure transmitters with electrical output for absolute pressure, differential pressure and excess pressure with negative and positive values.

Zwischenstand im Zusammenhang mit mutmaßlichen Messwertabweichungen beim Geschwindigkeitsüberwachungsgerät Leivtec XV3

Die Untersuchungen der PTB, ob es beim Geschwindigkeitsüberwachungsgerät Leivtec XV3 unter speziellen Bedingungen zu weiteren unzulässigen Messwertabweichungen kommen kann, sind noch nicht abgeschlossen.

Kalibrierung und Überprüfung der Drehmomentmesseinrichtung von Torsionsprüfmaschinen : Richtlinie DKD-R 9-1

Diese Richtlinie gilt für die statische Kalibrierung und Überprüfung von Torsionsprüfmaschinen nach einem Verfahren, welches auf der Kalibrierung von Werkstoffprüfmaschinen nach DIN EN ISO 7500-1 aufbaut. Die Überprüfung besteht aus einer allgemeinen Inspektion der Torsionsprüfmaschine einschließlich der Maschinenteile für die Torsionsaufbringung; einer Kalibrierung der Drehmomentmesseinrichtung der Torsionsprüfmaschine und einer Bestätigung, dass die ermittelten Eigenschaften der Torsionsprüfmaschine die für eine festgelegte Klasse angegebenen Grenzwerte einhalten. Diese RichtlinieDKD-R 9-1 betrifft die statische Kalibrierung und Überprüfung von Drehmomentmesseinrichtungen....

Puls-Elektrometer-Verstärker zur parallelen Messung von Strom und Ladung

Gerd Buchholz
Der Laborbericht beschreibt die Entwicklung und Anwendung eines Messgerätes zur gleichzeitigen Erfassung von sehr kleinen Strömen (im Bereich einiger 10-15 Ampere) sowie entsprechend kleinen Ladungen. Es wurde eine neuartige elektronische Beschaltung bestehend aus einer Kombination von Transimpedanzverstärker und Integrator entwickelt und eingesetzt. Anwendung findet das Messprinzip bei der Messung kleiner Ströme von Luftionisationskammern in gepulsten und kontinuierlichen Strahlungsfeldern. Für diese Anwendung wurde auch ein Muster-Prototyp zur mobilen Datenerfassung, Dosisanzeige inklusive Kommunikationsschnittstelle entwickelt.

The TILSAM method adapted into Optical Gas Standards - complementing gaseous reference materials

Olav Werhahn, Jan C. Petersen, Javis Nwaboh, Andrea Pogány & Zhechao Qu
TILSAM – Traceable Infrared Laser Spectrometric Amount fraction Measurement - has been available since 2009 [1]. Onboarded by a EURAMET research project and validated by a comparison study of ambient level carbon dioxide gas standards [2], this method has been successfully applied for CO2 and CO quantifications in greenhouse gas measurements, breath analysis studies, and industrial drying processes [3-6]. Facing new challenges in gas analysis related to an increasing number of critical analytes as well...

Die Erfassung von Beobachtungsdaten anhand der Erdmagnetfeldmessung in der PTB und Aspekte von Systemstandards, Sicherheit, Nachhaltigkeit und Qualitätssicherung

Hans Harcken
Der Laborbericht beschreibt die Infrastruktur und die eingesetzten Hard- und Software-Werkzeuge der Erdmagnetfeldmessung in der PTB am Standort Braunschweig als Beispiel für die Ermittlung und Erfassung von Beobachtungsdaten. Dazu wurden neuartige Methoden der Synchronisierung von Messplätzen unter Nutzung des Datennetzes der PTB eingesetzt. Besondere Berücksichtigung fanden dabei Aspekte der Nachhaltigkeit und Qualitätssicherung, um einen möglichst zuverlässigen und langlebigen automatischen Messbetrieb mit einer integrierten Veröffentlichung von Live-Daten im Internet sicherzustellen.

PTB-Anforderungen 12.13 „Abschnittskontrollsysteme (Section Control Systeme)“. Ausgabe Juli 2021

Diese PTB-Anforderungen behandeln folgende Messgeräte nach § 1 Absatz 1 Nummer 12 Buchstabe a der Mess- und Eichverordnung zur Bestimmung von Messgrößen im öffentlichen Verkehr zur amtlichen Überwachung: Abschnittskontrollsysteme (Section Control Systeme). Diese PTB-Anforderungen enthalten Anforderungen zu technischen Spezifikationen und Verwendungspflichten für Abschnittskontrollsysteme (Section Control Systeme). Sie wurden von der PTB unter Beteiligung der betroffenen Kreise erstellt. Diese PTB-Anforderungen bestehen aus zwei Teilen. Der erste Teil behandelt Regeln und technische Spezifikationen für Abschnittskontrollsysteme (Section Control...

Additional data for the publication \"Coherent Suppression of Tensor Frequency Shifts through Magnetic Field Rotation\"

Robert Lange, Nils Huntermann, Christian Sanner, Hu Shao, Burghard Lipphardt, Christian Tamm & Ekkehard Peik
Data on simulations of the magnetic field and on the frequency shift measurement of the E3 and E2 transition used for a determination of the quadrupole moments.

Dataset for the publication \"Umfrage zum Forschungsdatenmanagement in der Physik\"

Holger Israel, Esther Tobschall & Frank Tristram
Der Umgang mit Forschungsdaten gewinnt mit fortschreitender Digitalisierung an gesellschaftlicher Aufmerksamkeit. Während ein weitgehender Konsens zu den in den FAIR-Prinzipien dargestellten Anforderungen an gutes Forschungsdatenmanagement besteht, ist ihre Umsetzung eine längerfristige Aufgabe. Das im Rahmen der Nationalen Forschungsdateninfrastruktur (NFDI) gegründete Konsortium NFDI4Phys führte im Frühjahr 2020 eine Umfrage zur Ermittlung des status quo und der vordringlichen Bedarfe an das Forschungsdatenmanagement in der Physik durch. In diesem Dokument stellen wir die Methodik und detaillierte Auswertung der...

Collection of spectra of direct photons recorded in ISO neutron fields

Harald Dombrowski & Ralf Nolte
Compilation of prompt photon spectra recorded in ISO neutron fields produced at PIAF (PTB accelerator facility) by using a 1.5'' x 1.5'' CeBr3 detector. This data set is an appendix to the article “Quantitative investigation of gamma radiation in accelerator produced ISO neutron fields” by H. Dombrowski and R. Nolte. The spectra are depicted in this article. The time-of-flight method was used to detect direct photons. By performing shadow cone measurements, a background subtraction was...

Validation of measurement uncertainty budgets : Guide DKD-L 13-2

Braunschweig Physikalisch-Technische Bundesanstalt
This Guide is a tool for the validation of determined measurement uncertainties. It takes into account the determination of the smallest measurement uncertainty to be specified (best measurement uncertainty in the frame of the Calibration and measurement capability, CMC) as well as the representation of the measurement uncertainty assigned to an actual measurement, which is to be stated in test or calibration certificates. The Guide is intended for calibration and testing laboratories as well as...

Dataset for the publication \"Investigating the Trackability of Silicon Microprobes in High-Speed Surface Measurements\"

Min Xu, Zhi Li, Michael Fahrbach, Erwin Peiner & Uwe Brand
High-speed tactile roughness measurements set high demand on the trackability of the stylus probe. Because of the features of low mass, low probing force, and high signal linearity, the piezoresistive silicon microprobe is a hopeful candidate for high-speed roughness measurements. This paper investigates the trackability of these microprobes through building a theoretical dynamic model, measuring their resonant response, and performing tip-flight experiments on surfaces with sharp variations. Two microprobes are investigated and compared: one with...

Sinking Bubbles

Ophélie Lèna Riviére
Junge Wissenschaft. Paper 09/2021

PTB-Anforderungen 12.04 „Verkehrsradargeräte (stationär, transportabel)“. (11/2021)

Diese PTB-Anforderungen behandeln folgende Messgeräte nach § 1 Absatz 1 Nummer 12 Buchstabe a der Mess- und Eichverordnung zur Bestimmung von Messgrößen im öffentlichen Verkehr zur amtlichen Überwachung: Verkehrsradargeräte (stationär, transportabel). Diese PTB-Anforderungen enthalten Anforderungen zu technischen Spezifikationen und Verwendungspflichten für Verkehrsradargeräte. Sie wurden von der PTB unter Beteiligung der betroffenen Kreise erstellt. Diese PTB-Anforderungen bestehen aus zwei Teilen. Der erste Teil behandelt Regeln und technische Spezifikationen für Verkehrsradargeräte, um die wesentlichen Anforderungen an diese...

Rundung von Ergebnissen und Messunsicherheiten in Kalibrierscheinen : Leitfaden DKD-L 13-3

Messergebnisse werden als Messwert und Messunsicherheit ausgedrückt (Internationales Wörterbuch der Metrologie, VIM, Abschn. 2.9) und sind Bestandteil jeder Kalibrierung. Bei der Rundung eines Messwerts ist es erforderlich, die Anzahl der Ziffern des Messwertes des Messergebnisses (Ergebniswert) an die Messunsicherheit anzupassen, um keine Unsicherheit unterhalb ihrer eigentlichen Größenordnung zu suggerieren. Dieser Leitfaden fasst normative Regeln und Richtlinienvorgaben zusammen und liefert praktikable Strategien und Beispiele als Empfehlung für das richtige Runden. Messergebnisse im Sinne dieses Leitfadens sind...

Calibración estática de instalaciones de calibración para llaves dinamométricas : Directriz DKD-R 10-8

Braunschweig Physikalisch-Technische Bundesanstalt
En este documento, las instalaciones de calibración para llaves dinamométricas se denominan también dispositivos de calibración de llaves dinamométricas (o brevemente dispositivo de calibración). Esta directriz se aplica para calibrar instalaciones de calibración para llaves dinamométricas mediante llaves de transferencia de par de torsión sirviendo como patrones de transferencia y respalda los requisitos correspondientes de la norma DIN EN ISO 6789. Se describe un procedimiento para determinar la incertidumbre relativa de estos dispositivos. Esta directriz...

Bioreiniger für Textilabwasser

Fritz Henke
Junge Wissenschaft. Paper 02/2021

Calibration and verification of the torque measuring device of torsion testing machines : Guideline DKD-R 9-1

This guideline is applicable to the static calibration and verification of torsion testing machines using a procedure based on the calibration of materials testing machines according to DIN EN ISO 7500-1. The verification implies a general inspection of the torsion testing machine, including the parts used for the application of torque; a calibration of the torque measuring device of the torsion testing machine and a confirmation that the determined properties of the torsion testing machine...

PTB-Jahresbericht 2020

Anomalies in multiline-TRL-corrected measurements of short CPW lines

Gia Ngoc Phung & Uwe Arz
Microwave probes in on-wafer measurements contribute to a number of parasitic effects deteriorating the accuracy of multiline Thru Reflect Line (mTRL) calibrations. The accuracy of mTRL calibration is especially sensitive in Devices under Test (DUTs) of shorter line length. It has been demonstrated in previous experimental studies that the calibrated results are often only reliable as long as the length of the line is at least 2 mm. However, the reasons behind this phenomenon have...

Optimization of a Self-darkening System

Adrien Jathe
Junge Wissenschaft. Paper 08/2021