Evaluation of the Canadian Forces Injury Surveillance Pilot Project in Valcartier, Québec

Claudia L. Sarbu
Introduction: An injury surveillance system was piloted in 2011 to monitor injuries in Canadian Forces. This evaluation of the key system attributes examined system performance. Methods: A retrospective chart review, a coding reliability study, a completeness of forms study and a key informant interview. Results: Sensitivity was 0.36 (95% CI: 0.28, 0.46). The system was missing patients over age 35. Kappa coefficients over 0.80 demonstrated good agreement. Completeness of forms study demonstrated high percentages of...