Prediction of radiochromic film response for hadrontherapy dosimetry with Monte Carlo simulation in homogeneous and hetergeneous media

N. Zahra, T. Frisson, D. Sarrut & P. Lautesse
A model has been developed to calculate radiochromic lm response to ion irradiation. This model is based on photon film response and film saturation by high local energy deposition computed by Monte Carlo (MC) simulation. Validation has been performed with 95 MeV/u 12C beam and shows error less[for full text, please go to the a.m. URL]