Continuous monitoring of corticobulbar motor evoked potentials during skull base and brainstem surgery using the double train technique

Kathleen Seidel & Andreas Raabe
Objective: To optimize cranial nerve (CN) monitoring recording of corticobulbar motor evoked potentials (MEP) of the facial and the vagal nerve have been described recently. As conventional mapping techniques can only been applied intermittently, methods for continuous monitoring of the functional integrity[for full text, please go to the a.m. URL]