Moisture and mould growth in compact roofs – Results from a three-stage field survey

Jonas Holme, Knut Noreng, Tore Kvande & Jonas Holme
Compact roof systems that are done right, using materials that are not mould-prone between a correctly installed vapour barrier and the roof waterproofing membrane, have typically been considered to be not very moisture sensitive. Moisture in compact roofs has therefore perhaps not received sufficient attention. With large precipitation amounts in southern Norway in the fall of 2000, the theme of built-in moisture in compact roofs became relevant. Both in connection with roof work during periods...