Treatment of CSO water using floating plant beds

L. Buts, C. Thoeye & G. De Gueldre
A pilot installation treating a combined sewer overflow (CSO) at Bornem, Flanders is built. The construction comprises a presettler and a plug flow treatment zone with floating vegetation elements. The installation is aimed to treat efficiently a so-called two-year overflow event of 2,309 m\302\263 volume and 0.17 m\302\263/s peak flow. During the past three years a number of overflow events were registered. Initially the system performed well, with an observed COD-removal efficiency of 68% and...