The real issues with in-ground SUDS in Scotland

W. Schl\303\274ter & C. Jefferies
The aim of this research was to produce enhanced detailing and improved operation of in-ground SUDS. Data from on-site monitoring at three filter drain and three infiltration trench systems were analysed and the results were combined with information gathered from 40 assessments of in-situ systems in Eastern Scotland. Current findings showed that almost 50% of all systems were found to be unsatisfactory and more than half of these were rated as having failed. 36% provided...

1 Related Work

The real issues with in-ground SUDS in Scotland

W. Schl\303\274ter & C. Jefferies
The aim of this research was to produce enhanced detailing and improved operation of in-ground SUDS. Data from on-site monitoring at three filter drain and three infiltration trench systems were analysed and the results were combined with information gathered from 40 assessments of in-situ systems in Eastern Scotland. Current findings showed that almost 50% of all systems were found to be unsatisfactory and more than half of these were rated as having failed. 36% provided...