Test data for uniaxial tensile on material AISI 316 L at 24 Celsius

&
In this IBIS experiment (under the framework of the materials domain DEMETRA in the European Transmutation research and development project EUROTRANS) ferritic-martensitic 9 Cr steel (T91), austenitic 316L stainless steel and their welds in direct contact with LBE have been irradiated for 250 full power days up at 300 oC to a dose level of 1.25-1.8 dpa, and at 500 oC to a dose level of 2.1- 2.7 dpa. The results from the uni-axial tensile...