Investigating the origin of breakage of panes subjected to blast loading by acoustic emission testing

Jan Dirk Van Der Woerd
The Fraunhofer EMI shock-tube facility “Blast-STAR” is used to simulate blast loadings from high explosive detonations similar to realistic conditions. Mainly tests on explosion-resistant safety glazing and façades are carried out. Due to the extreme conditions during the test, it is not trivial to accurately analyze the specimen reaction and in particular to determine the start of breakage of the glass pane. Usually high-speed footage is used for this purpose. Since the size of tested...