7 Works

PSP FIELDS Fluxgate Magnetometer (MAG) Magnetic Field Vectors, Radial-Tangential-Normal, RTN, Coordinates, 4 samples/cycle, Level 2 (L2), 3.413 ms Data

Stuart D. Bale, Robert J. MacDowall, Andriy Koval, Marc Pulupa, Timothy Quinn & Peter Schroeder
Parker Solar Probe FIELDS Instrument Suite Fluxgate Magnetometer, MAG, Data: The time resolution of the MAG time series data varies with instrument mode ranging from 2.289 samples/s to 292.9 samples/s. These two data sampling rates corresponding to 2 samples or 256 samples per 0.874 s where 0.874 s is equal to 2^25 divided 38.4 MHz. The Magnetometer has four ranges: ±1024 nT, ±4096 nT, ±16,384 nT, and ±65,536 nT. The Magnetometer Range is selected by...

PSP FIELDS Fluxgate Magnetometer (MAG) Magnetic Field Vectors, Spacecraft, SC, Coordinates, 4 samples/cycle, Level 2 (L2), 3.413 ms Data

Stuart D. Bale, Robert J. MacDowall, Andriy Koval, Marc Pulupa, Timothy Quinn & Peter Schroeder
Parker Solar Probe FIELDS Instrument Suite Fluxgate Magnetometer, MAG, Data: The time resolution of the MAG time series data varies with instrument mode ranging from 2.289 samples/s to 292.9 samples/s. These two data sampling rates corresponding to 2 samples or 256 samples per 0.874 s where 0.874 s is equal to 2^25 divided 38.4 MHz. The Magnetometer has four ranges: ±1024 nT, ±4096 nT, ±16,384 nT, and ±65,536 nT. The Magnetometer Range is selected by...

Parker Solar Probe Ephemeris, Heliocentric Trajectories, Heliographic, Heliographic Inertial, and Solar Ecliptic Coordinates, HelioWeb, Daily Data

Adam Szabo
Heliocentric trajectories for Parker Solar Probe in Heliographic, HG, Heliographic Inertial, HGI, and Solar Ecliptic, SE, Coordinates.

IceCube Level 1 Radiance Data and Codes

Jie Gong & Dong Wu
This zipped meta data file can be expanded into two folders. One folder contains the daily calibrated Level 1 radiance and geolocation data in HDF5 format, and the other folder contains the main IDL codes that process the data and make plots (mainly for generating plots for the paper Gong et al. 2021 that is under review for Earth Science System Data journal). Both folders contain a README file in each to guide readers through...

PSP FIELDS Fluxgate Magnetometer (MAG) Magnetic Field Vectors, Spacecraft, SC, Coordinates, Level 2 (L2), 1 min Data

Stuart D. Bale, Robert J. MacDowall, Andriy Koval, Marc Pulupa, Timothy Quinn & Peter Schroeder
Parker Solar Probe FIELDS Instrument Suite Fluxgate Magnetometer, MAG, Data: The time resolution of the MAG time series data varies with instrument mode ranging from 2.289 samples/s to 292.9 samples/s. These two data sampling rates corresponding to 2 samples or 256 samples per 0.874 s where 0.874 s is equal to 2^25 divided 38.4 MHz. The Magnetometer has four ranges: ±1024 nT, ±4096 nT, ±16,384 nT, and ±65,536 nT. The Magnetometer Range is selected by...

PSP FIELDS Fluxgate Magnetometer (MAG) Magnetic Field Vectors, Radial-Tangential-Normal, RTN, Coordinates, Full Resolution, Level 2 (L2), 3.413 ms Data

Stuart D. Bale, Robert J. MacDowall, Andriy Koval, Marc Pulupa, Timothy Quinn & Peter Schroeder
Parker Solar Probe FIELDS Instrument Suite Fluxgate Magnetometer, MAG, Data: The time resolution of the MAG time series data varies with instrument mode ranging from 2.289 samples/s to 292.9 samples/s. These two data sampling rates corresponding to 2 samples or 256 samples per 0.874 s where 0.874 s is equal to 2^25 divided 38.4 MHz. The Magnetometer has four ranges: ±1024 nT, ±4096 nT, ±16,384 nT, and ±65,536 nT. The Magnetometer Range is selected by...

PSP FIELDS Fluxgate Magnetometer (MAG) Magnetic Field Vectors, Spacecraft, SC, Coordinates, Full Resolution, Level 2 (L2), 3.413 ms Data

Stuart D. Bale, Robert J. MacDowall, Andriy Koval, Marc Pulupa, Timothy Quinn & Peter Schroeder
Parker Solar Probe FIELDS Instrument Suite Fluxgate Magnetometer, MAG, Data: The time resolution of the MAG time series data varies with instrument mode ranging from 2.289 samples/s to 292.9 samples/s. These two data sampling rates corresponding to 2 samples or 256 samples per 0.874 s where 0.874 s is equal to 2^25 divided 38.4 MHz. The Magnetometer has four ranges: ±1024 nT, ±4096 nT, ±16,384 nT, and ±65,536 nT. The Magnetometer Range is selected by...

Registration Year

  • 2021
    7

Resource Types

  • Dataset
    7

Affiliations

  • Goddard Space Flight Center
    7
  • University of California, Berkeley
    5
  • Universities Space Research Association
    1